
Marca por confirmar · CDTs
Applications

Marca por confirmar · CDTs

LI-COR (HOBO, InTemp, LI-COR) · MX2205

LI-COR (HOBO, InTemp, LI-COR) · MX2306

LI-COR (HOBO, InTemp, LI-COR) · MX2307

LI-COR (HOBO, InTemp, LI-COR) · MX2308
Measures Temperature, RH & Photosynthetically Active Radiation (PAR) with LI-COR PAR sensor High-precision monitoring of PAR, temperature, and humidity with effortless Bluetooth data offload, ideal for monitoring environmental conditions—from agricultural…

LI-COR (HOBO, InTemp, LI-COR) · MX2309
Measures Temperature, RH & Solar Radiation with LI-COR 200R Pyranometer Research-grade, multiparameter microclimate monitoring solution with effortless Bluetooth data offload that continuously measures global solar radiation, temperature, and humidity. Ideal…

LI-COR (HOBO, InTemp, LI-COR) · MX2500-GUARD
The Anti-Biofouling Copper Guard can be used in addition to the standard electrode guard for protection against biofouling during deployment. The anti-biofouling guard uses copper to reduce biofouling, while still allowing proper water flow to the sensor.

LI-COR (HOBO, InTemp, LI-COR) · MX2500-CAL-BKR
The 118,29mm calibration beaker can be used to calibrate the HOBO MX pH Logger and to store calibration solutions.

LI-COR (HOBO, InTemp, LI-COR) · MX2500-CAL-KIT
The Calibration Kit includes pH 4.01, pH 7.00, pH 10.00 buffer solutions (475 mL bottles), and the 118,29mm calibration beaker (MX2500-CAL-BKR).

LI-COR (HOBO, InTemp, LI-COR) · MX2500-STORE-SOLN
The Electrode Storage Solution is used to properly store and condition the pH electrode that is used with the HOBO MX pH Logger. The purpose of the storage solution is to maintain the hydrated gel layer that is integral to accurate pH readings.

LI-COR (HOBO, InTemp, LI-COR) · MX2500-MAINT-KIT
The Maintenance Kit includes the Calibration Kit (MX2500-CAL-KIT) and the Electrode Storage Solution (MX2500-STORE-SOLN).

LI-COR (HOBO, InTemp, LI-COR) · MX2500-ELECTRODE
With its gel electrolyte and double Pellon® junction minimizing the chance of contamination of the reference electrolyte, this plastic-bodied electrode and the HOBO MX2501 pH and Temperature Data Logger are perfectly suited for environmental monitoring of…

LI-COR (HOBO, InTemp, LI-COR) · MX2502
Bluetooth logger with PAR, temperature, tilt sensors Delivers highest-accuracy measurements of photosynthetically active radiation (PAR), temperature, and tilt for both underwater and above water environments. Important Information Requires a compatible…

LI-COR (HOBO, InTemp, LI-COR) · MX801-DO-KIT

Marca por confirmar · T28ACO2
The measurement of dissolved carbon dioxide (excluding HCO3- and CO32-) in water is one of the mostimportant parameters for water monitoring. The T28ACO2 now a new membrane covered optical CO2 sensor with titanium housing and other improved characteristics.…

LI-COR (HOBO, InTemp, LI-COR) · T-MINOL-130-NL
Measure cold and hot water flow rates with this compact, affordable water meter. The small-sized T-MINOL-130-NL is designed for deployment in apartments, assisted living communities, and other commercial buildings. Please note, the T-MINOL is configured for…

Marca por confirmar · NUTRISENS
The NUTRISENS sensor is a multiparametric probe (nitrate and potassium) with analogue and/or SDI-12 output signal for measuring the concentration and trend of nitrates and potassium in the soil.

Marca por confirmar · ODOS-3000

DataFlow-Systems · EIC-ODYCT
The Odyssey® Conductivity and Temperature recorder encapsulates both the logger and sensors in one water proof housing. The salinity of free water is measured by induction where the conductivity alters the signal coupling between two sensor elements. At the…

fuehlersysteme · OF3/E
-30...+400°C PT100, PT1000, Ni, NTC, KTY stainless steel contacting block

LI-COR (HOBO, InTemp, LI-COR) · BASE-U-4
The Universal Optic USB Base Station and couplers are used to offload data from any HOBO® data logger with an Optic USB interface. The splash-resistant Optic USB Base Station connects to your computer via USB, while connecting to the data logger via an…

LI-COR (HOBO, InTemp, LI-COR) · BASE-U-1
The Pendant Base Station and Coupler provide fast optical infrared (IR) communication for easy data logger launch and readout of HOBO Pendant data loggers. The Base Station connects via USB to a host computer, while the Coupler attaches the data logger to the…

iks-industrial · ODOS-5000
First optical oxygen sensor with SCS interface! (Simulation Clark-Sensor) Perfect integration into running systems. The ideal substitute for your existing oxygen sensors. Your advantages singular calibration minimal operating costs suitable for fresh and salt…

Marca por confirmar · EIC28300-03
Outdoor CO2 Sensor with radiation shield and mounting brackets Range concentration: 0-2000ppm, 0-5000ppm, 0-10000 ppm Power Supply: 12-24VDC Output: 4-20mA,0-5V,RS485
Tell EIC Controls about your application.