AC Current/Voltage

Multifunctional Electric Power Meter with Data Logger

Reference
FU2200A

Price on request

FU2200A digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.

  • Power Supply (AC/DC) AC85-400V / DC85-330V
  • Measurement Parameters Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF;
  • Harmonics Total harmonics ratio of phase-voltage
  • Computation Forward active power energy
  • Measuring Range 0-400V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1
  • Measuring Accuracy Voltage: 0.5%RD±0.05%FS
Talk to a specialist

Overview

FU2200A Ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics. Back of power meter FU2200A with Ethernet port as photo shows here.

Features

  • True-RMS measuring parameters
  • ANSI and IEC 0.2 accuracy class
  • Power quality analysis
  • 4 quadrant energy
  • 2MB onboard memory, can be extended to 16M
  • Data logging
  • High-speed RS485, Ethernet port (option)
  • Measure individual harmonics from 2nd to 63st (option)
  • TOU, 4 Tariffs, 6 Seasons, 6 Schedules
  • Three years warranty
  • With PC management software; web browse data

Applications

  • Metering of distribution feeders, transformers, generators, capacitor banks and motors
  • Medium and low voltage systems
  • Commercial, industrial, utility
  • Power quality analysis
  • Data logging
  • Monitoring system

Parameters

Electrical parameters

Power Supply (AC/DC) | AC85-400V / DC85-330V
Power consumption: <4VA
Measurement Parameters | Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF;
Active Power(W); Reactive Power(Q); Apparent Power(S),
2nd to 63st harmonics(option)
Harmonics | Total harmonics ratio of phase-voltage
Total harmonics ratio of current
2nd to 63st harmonics ratio of phase-voltage
2nd to 63st harmonics ratio of current
Maximum Value & Minimum Value | Voltage, current, frequency, active power, reactive power, apparent power,demandP,demandQ, demandS.
Computation | Forward active power energy
Reverse active power energy
Forward active power energy
Reverse reactive power energy
Measuring Range | 0-400V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1
Measuring Accuracy | Voltage: 0.5%RD±0.05%FS
Current: 0.5%RD±0.05%FS
Active Power: 0.5%RD±0.05%FS
Reactive Power: 1.5%RD +0.05%FS
Apparent power: 0.5%RD +0.1%FS
Power Factor: 0.5%RD
Frequency: 0.05%RD
Active Energy: 0.5%
Maximum Demand | Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Display | Blue back-lit LCD Display
5 display figures
4 operation keys
Communication | Support RS-485 interface port, 32 (128) Networking
ModBus-TCP/IP SNMP communication protocol
Ethernet 10/100M port (RJ45)
Memory | 2M onboard memory,can be extended to 16M.
Data looger interval can set by end users from 1min to 60min.The default is 15min.
You can read the data through a PC, also you can select the data to diaplay and store from software.
Programmable | Measuring system: 3P4W/3P3W etc
Transformation Ratio: PT 1-10000; CT 1-10000
Energy Pulse | Provides active & reactive energy pulse output
Pulse parameters can be choosed
Range: 0.1-10000kWh/kvarh
Dry contact output (1Ax100V)
Connection Mode | 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2W
Baud | Baud: 1200-57600, Standard 38400
Mechanical parameters
Dimensions (L x W x H) (mm) | 96 x 96 x 12.8
Mounting | Panel mounting
Trepanning: 92x92mm
The thickness of installation: 51mm
Environmental conditions
Temperature | -5 to +50 °C
Humidity | 20%-95%RH, without condensation
Warranty | Three years warranty

Index

Parameters Accuracy Resolution Measuring range Show on the display
Voltage 0.20% 0.01V 0-400V 0.5-500kV
Current 0.20% 0.01mA 0-6.5A 5mA-50000A
Active power 0.50% 0.2W 0-2400W/phase -9999MW to +9999MW
Reactive power 2% 0.2var 0-2400var/phase -9999Mvar to +9999Mvar
Apparent power 0.50% 0.2VA 0-2400VA/phase 0-9999MVA
Active demand 0.50% 0.2W 0-2400W/phase -9999MW to +9999MW
Reactive demand 2% 0.2var 0-2400var/phase -9999Mvar to +9999Mvar
Apparent demand 0.50% 0.2VA 0-2400VA/phase 0 to 9999MVA
Power factor 0.005 0.0001 -2 -2
Frequency 0.01Hz 0.01Hz 45.000-65.000Hz 45.000-65.000Hz
Active energy 0.5%,0.2% (Option) 0.001kWh 0-999999.999kWh 0-99999999.9kWh
Reactive energy 2% 0.001kvarh 0-999999.999kvarh 0-99999999.9kvarh
Apparent energy 0.50% 0.001VAh 0-999999.999kVAh 0-99999999.9kVAh
Phase angle 0.1° 0.01° 0-359.99° 0-359.99°
Unbalance 2% 0.01% 0-300.00% 0-300.00%
PT ratio 1 1-10000
CT ratio 1 1-10000
Address code 1 1-253

Related products

EG4115 Core - 15 Input Meter Data Logger

LI-COR (HOBO, InTemp, LI-COR) · EG4115

EG4115 Core - 15 Input Meter Data Logger

The EG4115 Core is a 15-channel energy meter with 0.5% revenue-grade accuracy compliance and the ability to measure residential or commercial circuit panels, up to 3-phase 277/480VAC and 6900A. The meter has HomePlug AV powerline communication, an Ethernet…

View product

E50B2 Power & Energy Meter Sensor

LI-COR (HOBO, InTemp, LI-COR) · T-VER-E50B2

E50B2 Power & Energy Meter Sensor

Build better energy efficiency and power management with the E50B2 Power & Energy Meter. This cost-effective sensor is simple to deploy and can either be installed on standard DIN rail or be surface mounted. The E50B2 integrates with HOBO UX, U30, ZW, H22,…

View product

S-RTA-M006 RX Runtime Smart Sensor (6m cable)

LI-COR (HOBO, InTemp, LI-COR) · S-RTA-M006

S-RTA-M006 RX Runtime Smart Sensor (6m cable)

The RX Runtime Smart Sensor measures the percent ON of any AC-powered device with an AC current switch, and time ON (closed) of contact closures - ideal for equipment runtime monitoring, boiler efficiency monitoring, pump monitoring, and engine monitoring.…

View product

HOBO Motor On/Off Data Logger (346.795 measurements)

LI-COR (HOBO, InTemp, LI-COR) · UX90-004M

HOBO Motor On/Off Data Logger (346.795 measurements)

The HOBO Motor On/Off data logger records motor on and off conditions within an AC magnetic field with its internal sensor, or mechanical dry contact closures from external sensing devices. This data logger is ideal for tracking the usage & runtimes of…

View product

What do you need to measure?

Tell EIC Controls about your application.