Pressure

HOBO Water Level (30 ft) Data Logger

Reference
U20L-01

Price on request

The HOBO U20L-01 is a low-cost, research-grade water level data logger for continuously measuring water level and temperature in a wide range of underwater environments. It features 0.1% measurement accuracy, a polypropylene housing for use in both fresh and salt water, and a non-vented design for convenient and hassle-free deployment.

This data logger requires either the U-DTW-1 Waterproof Shuttle or the Base-U-4 Base Station for configuration and data offload, HOBOware software (free download). NOTE: HOBOware Pro is required when using the U-DTW-1 Waterproof Shuttle. See compatible items below.

  • **Factory Calibrated Range** 69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)
  • **Burst Pressure** 310 kPa (45 psia) or 18 m (60 ft) depth
  • **Water Level Accuracy*** Typical error: ±0.1% FS, 1.0 cm (0.03 ft) water
  • **Raw Pressure Accuracy**** ±0.3% FS, 0.62 kPa (0.09 psi) maximum error
  • **Resolution** <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
  • **Accuracy** ±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A in manual
Talk to a specialist

Overview

Highlighted Features

• Self-contained non-vented design enables easy deployment
• Ideal for use in both fresh and saltwater environments, including wells, streams, lakes, wetlands, and tidal areas
• Depths up to 30 feet
• Durable ceramic pressure sensor withstands freezing
• HOBOware Pro software provides easy conversion to accurate water level reading, fully compensated for barometric pressure (see demo), temperature, and water density.

Pressure (Absolute) and Water Level Measurements U20L-01


Operation Range | 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
Factory Calibrated Range | 69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)
Burst Pressure | 310 kPa (45 psia) or 18 m (60 ft) depth
Water Level Accuracy* | Typical error: ±0.1% FS, 1.0 cm (0.03 ft) water
Maximum error: ±0.2% FS, 2.0 cm (0.06 ft) water
Raw Pressure Accuracy** | ±0.3% FS, 0.62 kPa (0.09 psi) maximum error
Resolution | <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
Pressure Response Time (90%)*** | <1 second at a stable temperature; measurement accuracy also depends on temperature response time

Temperature Measurements

Operation Range | -20° to 50°C (-4° to 122°F)
Accuracy | ±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A in manual
Resolution | 0.10°C at 25°C (0.18°F at 77°F), see Plot A in manual
Response Time (90%) | 10 minutes in water (typical)
Stability (Drift) | 0.1°C (0.18°F) per year

Logger

Real-time Clock | ±1 minute per month 0° to 50°C (32° to 122°F)
Battery | 2/3 AA, 3.6 Volt lithium, factory-replaceable
Battery Life (Typical Use) | 5 years with 1 minute or greater logging interval
Memory (Non-volatile) | 64K bytes memory (approx. 21,700 pressure and temperature samples)
Weight | Approximately 154 g (5.43 oz) in air Approximately 53.9 g (1.9 oz) in fresh water
Dimensions | 3.18 cm (1.25 inches) diameter, 15.24 cm (6.0 inches) length; mounting hole 6.3 mm (0.25 inches) diameter
Wetted Materials | Polypropylene housing and lanyard; Viton and Buna-N O-rings; ceramic sensor in acetyl end cap; stainless steel screws suitable for saltwater
Logging Interval | Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours. Refer to the HOBOware User’s Guide for details.
Launch Modes | Immediate start and delayed start
Offload Modes | Offload while logging; stop and offload
Battery Indication | Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile.
Environmental Rating: | IP68
CE Compliant | The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).

  • Water Level Accuracy: With accurate reference water level measurement, known water density, accurate Barometric Compensation Assistant data, and a stable temperature environment.

** Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.

*** Changes in Temperature: Allow 20 minutes in water to achieve full temperature compensation of the pressure sensor. Maximum error due to rapid thermal changes is approximately 0.5%

Related products

HOBO Water Level (100 ft) Data Logger

LI-COR (HOBO, InTemp, LI-COR) · U20L-02

HOBO Water Level (100 ft) Data Logger

The HOBO U20L-02 is a low-cost, research-grade water level data logger for continuously measuring water level and temperature in a wide range of underwater environments. It features 0.1% measurement accuracy, a polypropylene housing for use in both fresh and…

View product

HOBO Four-Channel Data Node (1 Temp, 1 RH, 1 Analog and 1 Pulse)

LI-COR (HOBO, InTemp, LI-COR) · ZW-005

HOBO Four-Channel Data Node (1 Temp, 1 RH, 1 Analog and 1 Pulse)

The HOBO® ZW-005 is an easy-to-deploy, 4-channel wireless temperature/relative humidity data node. It includes an external 2m temperature/relative humidity sensor probe, and features one analog port, and one pulse input port. It wirelessly transmits data in…

View product

HOBO Water Level Data Logger Deluxe Kit (0 to 30,6 m)

LI-COR (HOBO, InTemp, LI-COR) · KIT-D-U20-02

HOBO Water Level Data Logger Deluxe Kit (0 to 30,6 m)

Combining high accuracy water level measurements with out-of-the-box convenience, this money-saving kit includes everything needed to start logging right away. It is ideal for monitoring water levels and temperatures in wells, streams, lakes and freshwater…

View product

HOBO Water Level Data Logger Deluxe Kit (0 to 4 m)

LI-COR (HOBO, InTemp, LI-COR) · KIT-D-U20-04

HOBO Water Level Data Logger Deluxe Kit (0 to 4 m)

Combining high accuracy water level measurements with out-of-the-box convenience, this money-saving kit includes everything needed to start logging right away. It is ideal for monitoring water levels and temperatures in wells, streams, lakes and freshwater…

View product

What do you need to measure?

Tell EIC Controls about your application.