AC Current/Voltage

S-RTA-M006 RX Runtime Smart Sensor (6m cable)

Reference
S-RTA-M006

Price on request

The RX Runtime Smart Sensor measures the percent ON of any AC-powered device with an AC current switch, and time ON (closed) of contact closures - ideal for equipment runtime monitoring, boiler efficiency monitoring, pump monitoring, and engine monitoring. This sensor is compatible with HOBO RX Stations.

  • Plug-and-play smart sensor
  • Works with all HOBO RX stations
  • Automatically communicates configuration data to the station
  • 1-second runtime resolution
  • 6m cable length
Talk to a specialist

Overview

Specifications

Input Sampling Period: 1 second
External Contact Input: Solid state switch closure, logic driven voltage output, or open/closed mechanical switch
Preferred Switch State: Normally open
Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 300 KΩ
Logic Signal Level: Logic 0: < 0.4 V DC, Logic 1: > 2.5 V DC
Internal Weak Pull-Up: 100 KΩ
Input Range: 0 to 3.6 V
User Connection: 24 AWG wires, 2 leads: white(+), black(-)
Operating Temperature Range: -40° to 75°C
Time Accuracy: ±4 seconds due to potential clock differences between the sensor and the station. Note that longer logging intervals can result in the maximum error.
Overall Cable Length: 6.5 m
Housing Materials: Weatherproof polyamide housing for smart sensor adapter
Length of Smart Sensor Cable*: 50 cm
Weight: 200 g
Number of Data Channels: 2
Bits per Sample: 12 bits for channel logging runtime as percent
16 bits for channel logging runtime in seconds
Measurement Averaging Option: No
Compliance Marks : CE Compliant UKCA - UK Declaration of Conformity

*A single HOBO RX station can accommodate 15 data channels and up to 100 m of smart sensor cable (the digital communications portion of the sensor cables).

Related products

Temperature/Relative Humidity (2m cable) Smart Sensor

LI-COR (HOBO, InTemp, LI-COR) · S-THC-M002

Temperature/Relative Humidity (2m cable) Smart Sensor

The Temperature/Relative Humidity Smart Sensor is designed to work with all Onset data loggers that accept smart sensors. All sensor parameters are stored inside the smart sensor, which automatically communicates configuration data information to the logger…

View product

CSV-A8 AC Current Switch Sensor

LI-COR (HOBO, InTemp, LI-COR) · CSV-A8

CSV-A8 AC Current Switch Sensor

Measure runtime (time-of-use) of equipment with the CSV-A8 split-core AC current sensor along with a compatible HOBO data logger. This UL-listed sensor has built-in on/off status lights and provides an adjustable current threshold of 0.5 to 175 amps. Simply…

View product

What do you need to measure?

Tell EIC Controls about your application.